Tue Jun 19 23:36:19 2012, yuta, Update, LSC, calibrated POY error signal  
|
Wed Jun 20 00:01:04 2012, Jenne, Update, LSC, calibrated POY error signal 
|
Wed Jun 20 18:43:57 2012, yuta, Update, LSC, calibrated POX error signal  
|
|
Message ID: 6841
Entry time: Wed Jun 20 18:43:57 2012
In reply to: 6834
|
Author: |
yuta |
Type: |
Update |
Category: |
LSC |
Subject: |
calibrated POX error signal |
|
|
[Jenne, Yuta]
We did the same calibration for POX. It was 3.8e12 counts/m. See elog #6834 for the details of calibration we did.
According to Kiwamu's calibration, actuator response of ITMX is;
A_ITMX = 4.913e-09 Hz^2*counts/m / freq^2
Plots below are results from our calibration measurement.
  
|