Entry  Fri Jun 1 14:56:08 2012, Jamie, Update, SUS, Oplevs all different, messed up oplevs.png
    Reply  Fri Jun 1 18:07:32 2012, steve, Update, SUS, Oplevs servo values 
    Reply  Fri Jun 1 19:48:54 2012, rana, Update, SUS, Oplevs all different, messed up 
    Reply  Wed Jul 11 16:19:08 2012, yuta, Update, SUS, oplev servo phiology 
Message ID: 6745     Entry time: Fri Jun 1 19:48:54 2012     In reply to: 6743
Author: rana 
Type: Update 
Category: SUS 
Subject: Oplevs all different, messed up 

 

 Its a good question, but the answer is yes. At some level all of the OL servos should be different to handle the different mechanical resonances of the suspension as well as the optical table's acoustic noise and the different noise requirements for the difference optical cavities.

However, it would be better to have the same basic structure and then one or two customization filters.