40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue May 29 14:59:39 2012, Jenne, Update, IOO, PMC, MC alignment are shit 
    Reply  Tue May 29 15:48:31 2012, Koji, Update, IOO, PMC, MC alignment are shit 
       Reply  Tue May 29 19:50:01 2012, Jenne, Update, IOO, PMC, MC alignment are shit 
          Reply  Tue May 29 21:05:30 2012, yuta, Update, IOO, PMC, MC alignment are shit 
    Reply  Tue May 29 17:40:45 2012, Jenne, Update, IOO, PMC, MC alignment are shit 
Message ID: 6709     Entry time: Tue May 29 21:05:30 2012     In reply to: 6708
Author: yuta 
Type: Update 
Category: IOO 
Subject: PMC, MC alignment are shit 

Quote:

  [Keiko, Jenne]

PMC aligned.  Suresh is fixing the measure MC spot positions script, then we'll remeasure MC spot positions.

 [Suresh, Jenne, Yuta]

We measured the MC spot positions twice tonight. Procedure for measuring them is in elog #6688.
The results were;

spot positions in mm (MC1,2,3 pit MC1,2,3 yaw):
    3.3359    3.9595    2.3171   -7.7424   -0.8406    6.4884

spot positions in mm (MC1,2,3 pit MC1,2,3 yaw):
    3.2681    4.0052    2.2808   -7.3965   -0.7624    7.1302

The spot moved by about 0.5 mm since May 25, but we concluded that this displacement is negligible and difficult to be fixed by aligning PSL beam.

We'll align Y arm and X arm next.