Entry  Tue May 29 14:59:39 2012, Jenne, Update, IOO, PMC, MC alignment are shit 
    Reply  Tue May 29 15:48:31 2012, Koji, Update, IOO, PMC, MC alignment are shit 
       Reply  Tue May 29 19:50:01 2012, Jenne, Update, IOO, PMC, MC alignment are shit 
          Reply  Tue May 29 21:05:30 2012, yuta, Update, IOO, PMC, MC alignment are shit 
    Reply  Tue May 29 17:40:45 2012, Jenne, Update, IOO, PMC, MC alignment are shit 
Message ID: 6708     Entry time: Tue May 29 19:50:01 2012     In reply to: 6704     Reply to this: 6709
Author: Jenne 
Type: Update 
Category: IOO 
Subject: PMC, MC alignment are shit 

Quote:

The followings are a kind of daily check. Do this without any notice:

- Align PMC.

Quote:

[Yuta, Jenne]

PMC and MC alignment are both shit, although with the WFS on, the MC is pretty good.  We're leaving it for now, so that (a) we don't mess up Koji's work, and (b) we can work on the Xarm.  Steve is doing Yarm oplev stuff, so we'll do Yarm later.

 

 [Keiko, Jenne]

PMC aligned.  Suresh is fixing the measure MC spot positions script, then we'll remeasure MC spot positions.