40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
|
Message ID: 668
Entry time: Mon Jul 14 19:15:43 2008
Reply to this: 669
|
Author: |
Alberto |
Type: |
Update |
Category: |
General |
Subject: |
abs cavity length measurement experiment |
|
|
Lately I've been dealing with the alignment of the interferometer to have a good beam spot at the AS port. Today the alignment script kept failing because of computer problems (failure of the frame builder) and also because the IFO was probably too far from the range where the automatic alignment works.
An other problem I keep having with the alignment of the optics on the AP table is with multiple reflection beams of the NPRO beam at the Farady.
Although I believe that now the two beams are quite well aligned, I don't see any reflection of the secondary beam from the IFO anymore.
It's like the more I try to improve the alignment, the worse I get from the beam matching. I'll keep working on this. |