40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed May 9 04:47:20 2012, Jenne, Update, Locking, PRM is really moving when PRMI locked PRM_louder_when_aligned.pdf
    Reply  Wed May 9 09:19:22 2012, Koji, Update, Locking, PRM is really moving when PRMI locked 
Message ID: 6631     Entry time: Wed May 9 09:19:22 2012     In reply to: 6629
Author: Koji 
Type: Update 
Category: Locking 
Subject: PRM is really moving when PRMI locked 

Is this enhancement of spectrum caused by the lock? Or by the actuation?

If this is also seen with approximately same amount of actuation to PRM POS,
this is just a suspension problem.

If this is only seen with the PRM locked, this is somehow related to the opt-mechanical coupling.

ELOG V3.1.3-