Wed Apr 18 08:53:50 2012, Jamie, Update, General, Power outage last night
|
Wed Apr 18 10:05:40 2012, Jamie, Update, General, Power outage last night
|
Wed Apr 18 11:46:14 2012, Jenne, Update, General, Power outage last night
|
Wed Apr 18 11:54:31 2012, Jenne, Update, General, Power outage last night
|
Thu Apr 19 09:45:43 2012, Suresh, Update, General, MC2 Oplev signals redirected for use in WFS servo
|
|
Message ID: 6549
Entry time: Thu Apr 19 09:45:43 2012
In reply to: 6544
|
Author: |
Suresh |
Type: |
Update |
Category: |
General |
Subject: |
MC2 Oplev signals redirected for use in WFS servo |
|
|
Quote: |
|
Quote:
- there are no oplev signals in MC1, MC2, and MC3
|
None of the 3 MC optics have oplevs, so there shouldn't be any oplev signals. Although MC2 has the trans QPD, which was once (still is??) going through the MC2 oplev signal path.
.......
|
The MC2 Oplev signal path has been modified in the c1mcs model. The ADC channels have been sent over the rfm into c1ioo model and are currently used in the WFS servo loops. Please see this elog 5397.
|