40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Wed Apr 18 08:53:50 2012, Jamie, Update, General, Power outage last night
|
Wed Apr 18 10:05:40 2012, Jamie, Update, General, Power outage last night
|
Wed Apr 18 11:46:14 2012, Jenne, Update, General, Power outage last night
|
Wed Apr 18 11:54:31 2012, Jenne, Update, General, Power outage last night
|
Thu Apr 19 09:45:43 2012, Suresh, Update, General, MC2 Oplev signals redirected for use in WFS servo
|
|
Message ID: 6543
Entry time: Wed Apr 18 10:05:40 2012
In reply to: 6542
Reply to this: 6544
|
Author: |
Jamie |
Type: |
Update |
Category: |
General |
Subject: |
Power outage last night |
|
|
All of the front-ends are back up and I've been able to recover local control of all of the opitcs (snapshots from saturday). Issues:
- I can't lock the PMC. Still unclear why.
- there are no oplev signals in MC1, MC2, and MC3
- Something is wrong with PRM. He is very noisy. Turning on his oplev servo makes him go crazy.
- There are all sorts of problems with the oplevs in general. Many of the optics have no oplev settings. This is probably not related to the power outage.
On a brighter note, ETMX is damped with it's new RCG 2.5 controller! yay! |