40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Apr 18 08:53:50 2012, Jamie, Update, General, Power outage last night 
    Reply  Wed Apr 18 10:05:40 2012, Jamie, Update, General, Power outage last night 
       Reply  Wed Apr 18 11:46:14 2012, Jenne, Update, General, Power outage last night 
          Reply  Wed Apr 18 11:54:31 2012, Jenne, Update, General, Power outage last night 
          Reply  Thu Apr 19 09:45:43 2012, Suresh, Update, General, MC2 Oplev signals redirected for use in WFS servo 
Message ID: 6543     Entry time: Wed Apr 18 10:05:40 2012     In reply to: 6542     Reply to this: 6544
Author: Jamie 
Type: Update 
Category: General 
Subject: Power outage last night 

All of the front-ends are back up and I've been able to recover local control of all of the opitcs (snapshots from saturday). Issues:

  • I can't lock the PMC.  Still unclear why.
  • there are no oplev signals in MC1, MC2, and MC3
  • Something is wrong with PRM.  He is very noisy.  Turning on his oplev servo makes him go crazy.
  • There are all sorts of problems with the oplevs in general.  Many of the optics have no oplev settings.  This is probably not related to the power outage.

On a brighter note, ETMX is damped with it's new RCG 2.5 controller!  yay!

ELOG V3.1.3-