Entry  Fri Apr 6 10:31:07 2012, Den, Update, Adaptive Filtering, static and adaptive static_oaf.pdf
    Reply  Fri Apr 6 11:14:34 2012, Jenne, Update, Adaptive Filtering, static and adaptive 
Message ID: 6492     Entry time: Fri Apr 6 10:31:07 2012     Reply to this: 6493
Author: Den 
Type: Update 
Category: Adaptive Filtering 
Subject: static and adaptive 

I've run static and adaptive filters simultaneously. AA32 filters rotate the phase of the witness signals GUR1X and GUR1Y and now the performance of the static filter is worse. Next time I'll recalculate Wiener filter coefficients taking this into account. But still 2 filters together can deal with a stack better.