Mon Mar 26 23:47:54 2012, Suresh, Update, IOO, Beam Profile measurement: IPPOS beam  
|
Tue Mar 27 02:05:40 2012, Suresh, Update, IOO, Beam Profile measurement: IPPOS beam 
|
Tue Mar 27 11:54:18 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam
|
Tue Mar 27 18:03:46 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam
|
Tue Mar 27 21:20:32 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam
|
Tue Mar 27 23:37:35 2012, Suresh, Update, IOO, Beam Profile measurement: IPPOS beam
|
Wed Mar 28 01:17:29 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam  
|
Wed Mar 28 18:26:47 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam   
|
Wed Mar 28 20:54:02 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam 
|
Mon Apr 2 18:58:32 2012, Jenne, Update, IOO, Beam Profile measurement: IPPOS beam
|
Mon Apr 2 23:06:38 2012, Suresh, Update, IOO, Beam Profile measurement: IPPOS beam: Mystery deepens  
|
Tue Mar 27 17:19:02 2012, Koji, Update, IOO, Beam Profile measurement: IPPOS beam
|
Tue Mar 27 02:18:31 2012, keiko, Update, IOO, Beam Profile measurement: IPPOS beam   
|
Tue Mar 27 16:06:59 2012, keiko, Update, IOO, Beam Profile measurement: IPPOS beam
|
|
Message ID: 6448
Entry time: Tue Mar 27 02:05:40 2012
In reply to: 6447
Reply to this: 6451
6453
|
Author: |
Suresh |
Type: |
Update |
Category: |
IOO |
Subject: |
Beam Profile measurement: IPPOS beam |
|
|
Quote: |
[Keiko, Suresh]
|
Vertical |
Horizontal |
Waist (mm) |
2.77 |
2.48 |
Rayleigh length (m) |
23.5m |
15.87 |
Waist location (m) |
0.81 m |
1.85 |

|
If we assume the nominal wavelength of the IR light to be 1064nm and constrain the Rayleigh length to be zr = (pi w0^2)/lambda we obtain the following fit parameters: (these are compared with the beam profile measurements of June/18/2010 available in the wiki )
|
Vertical |
Vertical
06/18/2010
|
Horizontal |
Horizontal
06/18/2010
|
waist (radius) (mm) |
2.77 |
2.81 |
2.47 |
2.91 |
Rayleigh length (m) (computed) |
22.62 |
|
18.14 |
|
Waist location w.r.t. to MM2 * |
3.37 |
5.36 |
4.15 |
1.96 |
* I updated the waist waist location coz because I missed-out the distance in air from the vacuum port to the optic on the IPPOS table.

|
|
|