Entry  Wed Mar 21 10:31:28 2012, steve, Update, SAFETY, AC power to ETMY turned off 
    Reply  Wed Mar 21 11:32:47 2012, steve, Update, SAFETY, AC power to ETMX turned off 
       Reply  Wed Mar 21 19:12:27 2012, steve, Update, Computers, AC power back on both ends 
          Reply  Thu Mar 22 16:45:06 2012, kiwamu, Update, CDS, c1scx and c1scy not properly running 
             Reply  Thu Mar 22 17:41:15 2012, suresh, Update, CDS, c1scx and c1scy not properly running 
                Reply  Thu Mar 22 23:43:56 2012, Koji, Update, CDS, c1scx and c1scy not properly running 
Message ID: 6439     Entry time: Thu Mar 22 23:43:56 2012     In reply to: 6438
Author: Koji 
Type: Update 
Category: CDS 
Subject: c1scx and c1scy not properly running 

Did you guys checked if the simplant switch is set to "REAL WORLD" mode?

Edit by KI:

Bingo ! The input signals were bypassed to the simplant. I switched the simplant settings to REAL WORLD and now both end suspensions are working fine.