40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Mar 16 06:17:56 2012, Suresh, Update, Electronics, REFL165 calibration : measurements IMG_0552.JPG
    Reply  Fri Mar 16 10:37:52 2012, Jenne, Update, Electronics, Jenne Laser 
    Reply  Fri Mar 16 16:01:53 2012, rana, Update, Electronics, REFL165 calibration : measurements 
       Reply  Mon Mar 19 21:25:31 2012, Suresh, Update, Electronics, REFL165 calibration : measurements 
Message ID: 6425     Entry time: Fri Mar 16 16:01:53 2012     In reply to: 6423     Reply to this: 6428
Author: rana 
Type: Update 
Category: Electronics 
Subject: REFL165 calibration : measurements 

 To characterize the RF V to counts we need to know the state of the whitening filter board. Was the filter on or off ? What was the value of the whitening gain slider?

ELOG V3.1.3-