40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Mar 16 06:17:56 2012, Suresh, Update, Electronics, REFL165 calibration : measurements IMG_0552.JPG
    Reply  Fri Mar 16 10:37:52 2012, Jenne, Update, Electronics, Jenne Laser 
    Reply  Fri Mar 16 16:01:53 2012, rana, Update, Electronics, REFL165 calibration : measurements 
       Reply  Mon Mar 19 21:25:31 2012, Suresh, Update, Electronics, REFL165 calibration : measurements 
Message ID: 6424     Entry time: Fri Mar 16 10:37:52 2012     In reply to: 6423
Author: Jenne 
Type: Update 
Category: Electronics 
Subject: Jenne Laser 

Quote:

Here is a picture of the small black breadboard on which I have put together the PD characterisation setup.  It would be great if we can retain this portable set up as it is, since we keep reusing it every couple of weeks.  It would be convenient if we can fiber couple the path to the PD under test with a 2m long fiber.  Then we will not have to remove the PD from the optical table while testing it. 

 This is totally sweet Suresh!  I don't remember how much more fiber is coiled up under the plate that has the "Jenne Laser" label, but there's a reasonable amount.  It's not 2m, but maybe we can just extend the blue snakey thing some?

ELOG V3.1.3-