Entry  Wed Mar 7 13:59:07 2012, Ryan Fisher, Summary, Computer Scripts / Programs, Alterations to base epics install for installing aLIGO conlog: 
    Reply  Wed Mar 7 18:00:39 2012, Ryan Fisher, Summary, Computer Scripts / Programs, Alterations to base epics install for installing aLIGO conlog: 
       Reply  Thu Mar 8 17:18:19 2012, Ryan Fisher, Summary, Computer Scripts / Programs, Alterations to base epics install for installing aLIGO conlog: 
          Reply  Fri Mar 9 11:02:56 2012, Ryan Fisher, Summary, Computer Scripts / Programs, Alterations to base epics install for installing aLIGO conlog: 
             Reply  Fri Mar 9 15:48:56 2012, Ryan Fisher, Summary, Computer Scripts / Programs, Alterations to base epics install for installing aLIGO conlog: 
                Reply  Fri Mar 9 16:28:10 2012, Ryan Fisher, Summary, Computer Scripts / Programs, Alterations to base epics install for installing aLIGO conlog: 
          Reply  Mon Jul 23 07:39:55 2012, Ryan Fisher, Summary, Computer Scripts / Programs, Alterations to base epics install for installing aLIGO conlog: 
Message ID: 6391     Entry time: Fri Mar 9 11:02:56 2012     In reply to: 6387     Reply to this: 6394
Author: Ryan Fisher 
Type: Summary 
Category: Computer Scripts / Programs 
Subject: Alterations to base epics install for installing aLIGO conlog: 

Too Many Fast Changing EPICS in New Conlog


I have been monitoring the new conlog, and it already has far too many rows.

I'm going through the list of channels to exclude in the update_channels script for the conlog that is currently running and removing them from
the monitored channels in the new conlog using the remove_channel_names file and the medm screen (we may want to just wipe out the tables
and start over after this is set properly, but for now I'm keeping them):
#-- Exclude a few uninteresting or obsolete categories
if ( $chan =~ m/^[BIJ]$/ ||
$chan =~ m/IOO-MC_PWR_IN/ ||
$chan eq "C1:PSL-FSS_SLOWDC" ||
$chan =~ m/PSL-STAT_.*_BITS/ ||
$chan =~ m/:IOO-PZTM[12]_(PIT|YAW)_BIAS$/ ||
$chan =~ m/DAQ.*_cycle/ ||
$chan =~ m/DAQ.*rtSeconds/ ||
$chan =~ m/C1:-.*/ ||
$chan =~ m/C1:SUP/ ||
$chan =~ m/C1:SP/ ||
$chan =~ m/C1:X/ ||
$chan =~ m/C1:TST/ ||
$chan =~ m/C1:RF/ ||
$chan =~ m/C1:UCT/ ||
$chan =~ m/C1:DU/ ||
$chan =~ m/C1:MCP/ ||
$chan =~ m/C1:MCS/ ||
$chan =~ m/C1:FEC/ ||
$chan =~ m/C1:PEM/ ||
$chan =~ m/C1:LSP/ ||
$chan =~ m/C1:NIO/ ||
$chan =~ m/C1:WFS/ ||
$chan =~ m/C1:ASC-WFS/ ||
$chan =~ m/C1:ASC-SP/ ||
$chan =~ m/C1:VG/ ||
$chan =~ m/C1:IOO-DOF/ ||
$chan =~ m/C1:IOO-EO/ ||
$chan =~ m/Name/ ||
$chan =~ m/DEFAULTNAME/ ||
$chan =~ m/:IOO-PZT.*OFFSET/ ||
$chan =~ m/PD_VAR$/ ||
$chan =~ m/_INMON$/ ||
$chan =~ m/_EXCMON$/ ||
$chan =~ m/_OUT16$/ ||
$chan =~ m/_OUTMON$/ ||
$chan =~ m/_OUTPUT$/ ||
$chan =~ m/_RSET$/ ||
$chan =~ m/_ALIVE$/ ||
$chan =~ m/VMon$/ ||
$chan =~ m/PDMon$/ ||
$chan =~ m/(BiasVMon|FE_PPOLL|MASTER_OVERFLOW|FSS_TIDALSET|CPU_LOAD|CDM
_STAT|State_Bits|INDCOFFSET)/ )

With these removals, only 15493 channels are being monitored now.