40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Feb 28 20:49:33 2012, kiwamu, Update, LSC, insalling OSA 
    Reply  Wed Feb 29 04:23:14 2012, kiwamu, Update, LSC, REFL OSA installed 
       Reply  Mon Mar 5 05:39:36 2012, kiwamu, Update, LSC, REFL OSA installed APtable.png
          Reply  Mon Mar 5 13:11:06 2012, kiwamu, Update, LSC, installed a long BNC cable for REFL OSA 
Message ID: 6354     Entry time: Mon Mar 5 13:11:06 2012     In reply to: 6352
Author: kiwamu 
Type: Update 
Category: LSC 
Subject: installed a long BNC cable for REFL OSA 

A long BNC cable was installed and now the REFL OSA signal is happily shown on an oscilloscope in the control room.

Quote from #6352

The OSA for the REFL beam is now fully functional.

The only thing we need is a long BNC cable going from the AP table to the control room so that we can monitor the OSA signal with an oscilloscope.

ELOG V3.1.3-