I have hooked the ALS beatbox into the c1ioo DAQ. In the process, I did some rewiring so that the channel mapping corresponds to what is in the c1gcv model.
The Y-arm beat PD is going through the old proto-DFD setup. The non-existant X-arm beat PD will use the beatbox alpha.
Y coarse I (proto-DFD) --> c1ioo ADC1 14 --> C1:ALS_BEATY_COARSE_I
Y fine I (proto-DFD) --> c1ioo ADC1 15 --> C1:ALS_BEATY_FINE_I
X coarse I (bbox alpha)--> c1ioo ADC1 02 --> C1:ALS_BEATX_COARSE_I
X fine I (bbox alpha)--> c1ioo ADC1 03 --> C1:ALS_BEATX_FINE_I
This remapping required coping some filters into the BEATY_{COARSE,FINE} filter bank. I think I got it all copied over correctly, but I might have messed something up. BE AWARE.
We still need to run a proper cable from the X-arm beat PD to the beatbox.
I still need to do a full noise/response characterization of the beatbox (hopefully this weekend). |