I locked the PRMI with the AS55I and Q combination.
It seems the glitche rate decreased,
but I am not 100 % sure because the rest of the demod signals (i.e. REFL11 and etc) were showing relatively big signals (noise ?), which may cover the glitches.
Also the optical gain of PRCL at AS55I doesn't agree with my expectation based on the obtained sensing matrix (#6283).
It looks too low and lower than the measured sensing matrix by a factor of 50 or so.
I will continue working on this configuration tomorrow and then move on to the SRMI locking as a part of the glitch hunting activity.
Quote from #6287 |
So why don't you use AS55I and Q for the control of PRMI???
|
|