Wed Feb 15 05:29:22 2012, kiwamu, Update, LSC, sensing matrix of PRMI
|
Wed Feb 15 17:15:33 2012, kiwamu, Update, LSC, sensing matrix of PRMI 
|
Thu Feb 16 07:38:24 2012, Koji, Update, LSC, sensing matrix of PRMI
|
Fri Feb 17 04:45:48 2012, kiwamu, Update, LSC, sensing matrix of PRMI
|
Thu Feb 16 13:12:30 2012, rana, Update, LSC, sensing matrix of PRMI
|
|
Message ID: 6289
Entry time: Thu Feb 16 13:12:30 2012
In reply to: 6283
|
Author: |
rana |
Type: |
Update |
Category: |
LSC |
Subject: |
sensing matrix of PRMI |
|
|
Quote: |
I think I have told a lie in the last meeting -- the measured sensing matrix doesn't look similar to what Optickle predicts.
Smells like something is very wrong.
|
Those Radar plots are awesome. Even more awesome would be if they were in units of W/m (so that it can be directly compared with Optickle) and so that the numbers are useful even 1 year from now. Otherwise, we will lose the RF transimpedance information and thereby lose everything.