Entry  Fri Jan 27 06:07:47 2012, kiwamu, Update, LSC, glitch hunting 
    Reply  Fri Jan 27 17:16:05 2012, kiwamu, Update, LSC, hypothetical glitch scenario 
    Reply  Thu Feb 16 03:47:16 2012, kiwamu, Update, LSC, glitch table 
       Reply  Wed Feb 22 01:53:57 2012, kiwamu, Update, LSC, update on glitch table 
Message ID: 6284     Entry time: Thu Feb 16 03:47:16 2012     In reply to: 6231     Reply to this: 6303
Author: kiwamu 
Type: Update 
Category: LSC 
Subject: glitch table 

I updated the table which I posted some time ago (#6231). The latest table is shown below.

It seems that the glitches show up only when multiple DOFs are locked.

Interesting thing is that when the low finesse PRMI is locked with a big MICH offset (corresponding to a very low finesse) it doesn't show the glitches.

Qualitatively speaking, the glitch rate becomes higher as the finesse increases.

I will try SRMI tomorrow as this is the last one which I haven't checked the presence of the glitches.

 

 

 Yarm

(POY11 -->

ETMY)

Xarm

(POX11 --> ETMX)

MICH

(AS55-->BS)

or

(AS55 --> ITMs)

Half PRMI

(REFL11 --> PRM)

or

(REFL33 --> PRM)

low finesse PRMI

(ASDC --> ITMs)

(REFL33 --> PRM)

PRMI (carrier)

(AS55 --> ITMs)

(REFL33 --> PRM)

PRMI (sideband)

(AS55 --> ITMs)

(REFL33 --> PRM)

DRMI
AS55 NO NO NO NO glitch (depends on finesse)
glitch glitch glitch
REFL11 NO NO NO NO glitch (depends on finesse)
glitch glitch glitch
REFL33 NO NO NO NO - glitch glitch glitch
REFL55 NO NO NO NO glitch(depends on finesse) glitch glitch glitch
REFL165 NO NO NO - - - - -
POX11 - NO NO NO  - glitch glitch glitch
POY11 NO - NO NO  - glitch glitch glitch
POP55 - - - -  -  - - -
                 

 

 