Fri Feb 10 02:35:29 2012, kiwamu, Update, IOO, crazy ground motion
|
Fri Feb 10 11:01:31 2012, steve, Update, IOO, crazy ground motion
|
Fri Feb 10 11:46:44 2012, steve, Update, IOO, seismic noise back to normal  
|
Fri Feb 10 15:47:38 2012, rana, Update, PEM, seismic noise back to normal
|
Fri Feb 10 15:52:35 2012, Jenne, Update, PEM, seismic BLRMS loud too
|
Fri Feb 10 23:58:30 2012, rana, Update, PEM, seismic BLRMS loud too
|
Mon Feb 13 11:30:51 2012, Jenne, Update, PEM, seismic BLRMS loud too
|
Mon Feb 13 12:02:17 2012, Koji, Update, PEM, seismic BLRMS loud too
|
Fri Feb 10 23:19:09 2012, kiwamu, Update, IOO, cross talk causing fake seimometer signals
|
|
Message ID: 6271
Entry time: Fri Feb 10 15:47:38 2012
In reply to: 6269
Reply to this: 6272
|
Author: |
rana |
Type: |
Update |
Category: |
PEM |
Subject: |
seismic noise back to normal |
|
|
Kiwamu and Steve maybe don't know about how to trend seismic noise. If you just take the mean of the time series, you don't prove that the seismic noise got any higher. The STS has a nominally zero DC output, so the long period level shifts that you see tell you just that there was a DC offset.
This is NOT an increase in seismic noise. To see a seismic trend you should plot the trend of the BLRMS channels that we made especially for this purpose. |