Author: steve 
Type: Update 
Category: SUS 
Subject: ALL oplev YAW transfer functions 

Quote:

SUS- BS, ITMX, ITMY, PRM, SRM, ETMX & ETMY_OLPIT transfer funtion with sine wave excitation 0.1 amplitude:

 

OL_YAW transfer functions are here.

 I had two PHDs helping me to overlap the EXML files in DTT. We failed. This job requires professorial help.

Attachment 1: BS-OLYAW.1ampl.png  65 kB  | Show | Hide all | Show all
Attachment 2: ITMX-OLYAW.1ampl.png  65 kB  | Show | Hide all | Show all
Attachment 3: ITMY-OLYAW.1ampl.png  64 kB  | Hide | Hide all | Show all
ITMY-OLYAW.1ampl.png
Attachment 4: PRM_OLYAW.1.png  66 kB  | Hide | Hide all | Show all
PRM_OLYAW.1.png
Attachment 5: SRM_OLYAW.1ampl.png  65 kB  | Show | Hide all | Show all
Attachment 6: ETMX-OLYAW.1ampl.png  65 kB  | Hide | Hide all | Show all
ETMX-OLYAW.1ampl.png
Attachment 7: ETMY-OLYAW.1ampl.png  65 kB  | Show | Hide all | Show all
ELOG V3.1.3-