Entry  Mon Feb 6 17:06:11 2012, steve, Update, SUS, oplev transferfunction of PIT: ETMY & ETMX ETMX_PIT.pngETMY_PIT.png
    Reply  Tue Feb 7 16:30:46 2012, steve, Update, SUS, ALL oplev PIT transfer functions 7x
       Reply  Thu Feb 9 16:46:02 2012, steve, Update, SUS, ALL oplev YAW transfer functions 7x
          Reply  Thu Feb 23 10:53:54 2012, steve, Update, SUS, oplev PIT transfer functions oplPITtrans.pdf
             Reply  Mon Feb 27 14:35:22 2012, steve, Update, SUS, oplev YAW transfer functions oplYAWtransf.pdf
Message ID: 6263     Entry time: Thu Feb 9 16:46:02 2012     In reply to: 6259     Reply to this: 6309
Author: steve 
Type: Update 
Category: SUS 
Subject: ALL oplev YAW transfer functions 

Quote:

SUS- BS, ITMX, ITMY, PRM, SRM, ETMX & ETMY_OLPIT transfer funtion with sine wave excitation 0.1 amplitude:

 

OL_YAW transfer functions are here.

 I had two PHDs helping me to overlap the EXML files in DTT. We failed. This job requires professorial help.

Attachment 1: BS-OLYAW.1ampl.png  65 kB  | Show | Hide all | Show all
Attachment 2: ITMX-OLYAW.1ampl.png  65 kB  | Show | Hide all | Show all
Attachment 3: ITMY-OLYAW.1ampl.png  64 kB  | Hide | Hide all | Show all
ITMY-OLYAW.1ampl.png
Attachment 4: PRM_OLYAW.1.png  66 kB  | Show | Hide all | Show all
Attachment 5: SRM_OLYAW.1ampl.png  65 kB  | Show | Hide all | Show all
Attachment 6: ETMX-OLYAW.1ampl.png  65 kB  | Show | Hide all | Show all
Attachment 7: ETMY-OLYAW.1ampl.png  65 kB  | Hide | Hide all | Show all
ETMY-OLYAW.1ampl.png
ELOG V3.1.3-