40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Feb 6 17:06:11 2012, steve, Update, SUS, oplev transferfunction of PIT: ETMY & ETMX ETMX_PIT.pngETMY_PIT.png
    Reply  Tue Feb 7 16:30:46 2012, steve, Update, SUS, ALL oplev PIT transfer functions 7x
       Reply  Thu Feb 9 16:46:02 2012, steve, Update, SUS, ALL oplev YAW transfer functions 7x
          Reply  Thu Feb 23 10:53:54 2012, steve, Update, SUS, oplev PIT transfer functions oplPITtrans.pdf
             Reply  Mon Feb 27 14:35:22 2012, steve, Update, SUS, oplev YAW transfer functions oplYAWtransf.pdf
Message ID: 6259     Entry time: Tue Feb 7 16:30:46 2012     In reply to: 6257     Reply to this: 6263
Author: steve 
Type: Update 
Category: SUS 
Subject: ALL oplev PIT transfer functions 

SUS- BS, ITMX, ITMY, PRM, SRM, ETMX & ETMY_OLPIT transfer funtion with sine wave excitation 0.1 amplitude:

 

Attachment 1: BS_PIT.png  64 kB  | Hide | Hide all | Show all
BS_PIT.png
Attachment 2: ITMX_PIT.png  64 kB  | Hide | Hide all | Show all
ITMX_PIT.png
Attachment 3: itmy_pit.png  63 kB  | Hide | Hide all | Show all
itmy_pit.png
Attachment 4: PRM_PIT.png  64 kB  | Hide | Hide all | Show all
PRM_PIT.png
Attachment 5: SRM_PIT.png  64 kB  | Hide | Hide all | Show all
SRM_PIT.png
Attachment 6: ETMX_PIT.png  64 kB  | Hide | Hide all | Show all
ETMX_PIT.png
Attachment 7: ETMY_PIT2.png  64 kB  | Show | Hide all | Show all
ELOG V3.1.3-