Entry  Fri Feb 3 14:44:33 2012, Jenne, Update, IOO, MC SUS misalignment SUSjump_3Feb2012.png
    Reply  Fri Feb 3 15:49:10 2012, Jenne, Update, IOO, MC SUS misalignment 
    Reply  Fri Feb 3 17:17:47 2012, Den, Update, IOO, MC SUS misalignment 
Message ID: 6248     Entry time: Fri Feb 3 17:17:47 2012     In reply to: 6244
Author: Den 
Type: Update 
Category: IOO 
Subject: MC SUS misalignment 

Quote:

Reminder / Moral:  Everything cannot be considered to be "working fine" if the MC isn't locking.  See if you can figure out why, and especially if it's something that you screwed up, either fix it, or better yet, ask for help and learn how to fix what you broke.

When I left this morning, Steve was still working with the MC and it was unlocked anyway, I could not check it. By "fine" I meant only watchdogs. The thing is that before starting to work with c1lsc I turned off all the coils. Crazyness that Steve saw was after I turned them on back after reboot. This is a confusing thing - restarting models on c1lsc and burt restoring them is not enough. After I did it, everything at the STATUS MEDM screen was green, but the C1:SUS-???_??PD_VAR values went up after turning on coils. So sus and lsc communicated in a bad manner after the reboot. After restarting x02 model, the watchdogs were fine again.