Entry  Wed Dec 14 14:30:43 2011, Jenne, Update, RF System, LO for new demod box 
    Reply  Wed Dec 14 16:19:46 2011, Zach, Update, RF System, LO for new demod box 
       Reply  Wed Dec 14 18:06:39 2011, Zach, Update, RF System, LO for new demod box 
          Reply  Wed Dec 14 19:59:12 2011, Jenne, Update, RF System, LO for new demod box 
Message ID: 6119     Entry time: Wed Dec 14 14:30:43 2011     Reply to this: 6121
Author: Jenne 
Type: Update 
Category: RF System 
Subject: LO for new demod box 

The Rich demod box wants 10dBm for the local oscillator inputs, so I measured the values that we have coming out of the distribution box.  I'm using the "Spare 55MHz" and the "POP11" outputs, both of which had terminators so were not in use. 

The 55MHz had ~600mV peak, so between 5 and 6 dBm. 

The 11MHz had ~800mV peak, so about 8 dBm.

This is not enough dBm for either.  Going in search of RF amplifiers now...