40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Nov 29 18:31:40 2011, Den, Update, digital noise, Foton error 
    Reply  Thu Dec 1 18:30:39 2011, Vladimir, Den, Update, digital noise, Foton error 
       Reply  Fri Dec 2 17:43:46 2011, rana, Update, digital noise, Foton error 
          Reply  Wed Dec 7 20:55:44 2011, Vladimir, Den, Update, digital noise, Matlab error gain_cmp.png
Message ID: 6062     Entry time: Fri Dec 2 17:43:46 2011     In reply to: 6061     Reply to this: 6083
Author: rana 
Type: Update 
Category: digital noise 
Subject: Foton error 

It would be useful to see some plots so we could figure out exactly what magnitude and phase error correspond to "gross" and "miserable".

ELOG V3.1.3-