Message ID: 6061     Entry time: Thu Dec 1 18:30:39 2011     In reply to: 6041     Reply to this: 6062
Author: Vladimir, Den 
Type: Update 
Category: digital noise 
Subject: Foton error 

Foton Matlab Error     

We investigated some more the discrepancy between Matlab and Foton numbers. The comparison of cheby1(k, 1, 2*12/16384) was done between versions implemented in Matlab, R and Octave. Filters created by R and Octave agree with Foton.

Also, we found that Matlab has gross precision errors for cutoff frequencies just smaller than used in our fitler, for example cheby1(6, 2*3/16384) fails miserably.