The PSL alignment into the MC was too poor for the autolocker to engage. So retaining the last coil slider settings on the MC_Align screen that Kiwamu wanted, I have realigned the PSL beam and recentered the beam on the WFS.
When the WFS_MASTER was burtrestored after the recent power shutdown, the values loaded into the output matrix were not optimal. When we switch on the WFS loops now, the MC_TRANS loops seem to push the WFS into away from the best possible coupling to PSL. So I have switched them off for now. Will load a new optimised output matrix and measure the transfer functions to see what is going on.
|