40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 5969     Entry time: Mon Nov 21 15:47:58 2011
Author: Mirko 
Type: Update 
Category: IOO 
Subject: Osem loop shape 

[Jenne, Mirko]

To reiterate: We changed the OSEM loop shape for MC1-MC3. Below in black is the old loop shape, which simulated pendulum response in there. In red is the new loop shape.

OsemFilterShape.pdf

The differences are due to extra filter in C1:SUS-MC?_SUSPOS module 6,7,9

6: Elliptical LP @ 2.5Hz
7: Inverse Chebychev HP @0.3Hz
8: 1st order LP @ 10Hz

This has the potential to be unstable, but is not. At some point these filters should be tuned further.