40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sat Nov 12 02:27:00 2011, Suresh, Update, Computers, C1IOO front end suddenly froze. Was restarted remotely 
    Reply  Sat Nov 12 02:44:18 2011, Suresh, Update, Computers, C1IOO front end suddenly froze. Was restarted remotely 
Message ID: 5881     Entry time: Sat Nov 12 02:44:18 2011     In reply to: 5880
Author: Suresh 
Type: Update 
Category: Computers 
Subject: C1IOO front end suddenly froze. Was restarted remotely 

Quote:

[Koji Suresh]

No one was messing with the c1ioo or any other machine.   The medm screens for WFS and MC alignment froze while I was working on Rossa.

There were number of red lights pertaining to c1ioo machine on the CDS_FR_STATUS screen.  So we logged into c1ioo   from Rossa and restarted it with 'sudo shutdown -r now'.  It came back up but the C1IOO_MC_TRANS_SUM, P and Y signals were not available on the C1IOO LOCKMC screen.

I saw several messages similar to the one here


Sat Nov 12 02:09:14 PST 2011

  medmCAExceptionHandlerCb: Channel Access Exception:
  Channel Name: Unavailable
  Native Type: Unavailable
  Native Count: 0
  Access: Unavailable
  IOC: Unavailable
  Message: Virtual circuit disconnect
  Context: c1ioo.martian:43553
  Requested Type: TYPENOTCONN
  Requested Count: 0
  Source File: ../cac.cpp
  Line number: 1126

 

The MC autolocker script wasnt running.  The heartbeat bit was not blinking on the MC_LOCKMC screen.  So we manually restarted the script.  Hopefully it will return to normal operation.

I restarted the fb at Sat Nov 12 02:12:19 PST 2011  in an attempt to see this resolves the problem.

It didnt.

 

 The problem was resolved after I burtrestored (c1mcs c1ioo and c1rfm) epics snapshots.

 

ELOG V3.1.3-