40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 5878     Entry time: Fri Nov 11 22:07:43 2011
Author: Suresh 
Type: Update 
Category: IOO 
Subject: Tried to recover the MC alignment of 4th Nov: partial success, PSL beam clipping 

I have recovered the yaw values pretty much .  As the PZT1 rails in this direction perhaps this is the more relevant of the two alignments.  The beam is translated in the vertical direction, but this can be easily corrected by changing the pitch of MC2

However note that if the WFS are switched on .. MC is going to follow the PSL beam. 

 

 

 Date  #### MC1P MC2P MC3P MC1Y MC2Y MC3Y
03Nov2011   0.1354 -0.2522 -0.1383 -1.0893 0.7122 -1.5587
04Nov2011   4.0411 4.4994 3.5564 -1.4170 -0.2606 -1.7109
08Nov2011   4.7341 4.8794  4.3907 1.3542 -3.0508 -1.7167
10Nov2011    1   3.9944 3.7676 6.1001 -1.3058 -3.8087 -1.6418
11Nov2011    1  3.8542 3.6831 3.0418 -0.8383 0.1550 -2.3841
11Nov2011    2    3.6876 2.7429 2.7830 -1.6250 -0.0386 -1.6346

 

 