40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Nov 11 00:55:53 2011, Den, Update, Adaptive Filtering, MC_F mcl_sim.jpgmcl_real.jpg
    Reply  Fri Nov 11 10:30:27 2011, rana, Update, Adaptive Filtering, MC_F 
Message ID: 5871     Entry time: Fri Nov 11 10:30:27 2011     In reply to: 5869
Author: rana 
Type: Update 
Category: Adaptive Filtering 
Subject: MC_F 

 

 There should be a whitening filter in the Pentek Generic DAQ board (Eurocard with 8 differential LEMO inputs). It used to be that the MC_L channel came in through here and I believe it has 2 stages of 150:15 pole:zero filters.

I don't remember if it is one or two stages, but this should be easy to measure with a function generator or by driving this input using the MC2 UL Coil monitor and doing the transfer function in DTT (as Koji and Jenne did for the demod boards).

ELOG V3.1.3-