Entry  Tue Oct 25 01:14:15 2011, Suresh, Update, IOO, C1IOO model modified to include new WFS lockin structure c1ioo20111025.png
    Reply  Tue Oct 25 16:24:58 2011, Suresh, Update, IOO, C1IOO model modified to include new WFS lockin structure 
       Reply  Tue Oct 25 18:50:22 2011, Suresh, Update, IOO, C1IOO model modified to include new WFS lockin structure 
          Reply  Wed Jun 19 15:07:20 2013, rana, Update, IOO, WFS debugging 
             Reply  Thu Jun 20 15:15:39 2013, rana, Update, IOO, WFS debugging Untitled.png
                Reply  Thu Jun 20 20:46:16 2013, gautam, Update, IOO, WFS debugging-QPD debugging MC2_QPD-map.png
                Reply  Tue Jul 9 20:09:53 2013, Koji, Update, IOO, WFS debugging 
                Reply  Sun Oct 6 23:43:07 2013, rana, Update, IOO, WFS debugging 
Message ID: 5737     Entry time: Tue Oct 25 18:50:22 2011     In reply to: 5735     Reply to this: 8724
Author: Suresh 
Type: Update 
Category: IOO 
Subject: C1IOO model modified to include new WFS lockin structure 

Some small fixes to the c1ioo model.

1) I edited the WFS lockin modules to make use of new library part called demod.

2) c1ioo model has been compiled and restarted.

3) fb was restarted at Tue Oct 25 18:43:55 PDT 2011

 

Quote:

I forgot to mention another change I made to the C1IOO model.

The location of the WFS global switch has been shifted. It now cuts off signals just before the WFS servo filters.

I have also added some test points just before the switch so that we can monitor the WFS sensor signals even if the switch is off.

 

 

Quote:

A while back we faced the problem that when we use several lockins to excite the MC degrees of freedom, their relative phase was not known.  The solution suggested was to use one oscillator and several demodulators.

I have now modified the C1IOO.mdl so that this can be implemented.  Previously we were using the MC_ASS lockins for WFS work.  I have not separated the WFS and MC_ASS structures. 

Other jobs to be done in this context are:

1) The medm screens associated with WFS lockins need to be updated with new channel names.

2) The scripts associated with both MC_ASS decentering and WFS ouput matrix determination have to be updated with the new channel names.

3) I also deleted all mdem screens in the $screens$/c1ioo/ directory after copying them to $screens$/c1ioo/bak/.  After installing the new c1ioo model $screens$/c1ioo model now contains just the automatically created screens.  All other user made screens should to into $screens$/c1ioo/master/ directory

This is a pic of the new c1ioo model:

 

 c1ioo20111025.png

 

 

 