40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Oct 25 01:14:15 2011, Suresh, Update, IOO, C1IOO model modified to include new WFS lockin structure c1ioo20111025.png
    Reply  Tue Oct 25 16:24:58 2011, Suresh, Update, IOO, C1IOO model modified to include new WFS lockin structure 
       Reply  Tue Oct 25 18:50:22 2011, Suresh, Update, IOO, C1IOO model modified to include new WFS lockin structure 
          Reply  Wed Jun 19 15:07:20 2013, rana, Update, IOO, WFS debugging 
             Reply  Thu Jun 20 15:15:39 2013, rana, Update, IOO, WFS debugging Untitled.png
                Reply  Thu Jun 20 20:46:16 2013, gautam, Update, IOO, WFS debugging-QPD debugging MC2_QPD-map.png
                Reply  Tue Jul 9 20:09:53 2013, Koji, Update, IOO, WFS debugging 
                Reply  Sun Oct 6 23:43:07 2013, rana, Update, IOO, WFS debugging 
Message ID: 5732     Entry time: Tue Oct 25 01:14:15 2011     Reply to this: 5735
Author: Suresh 
Type: Update 
Category: IOO 
Subject: C1IOO model modified to include new WFS lockin structure 

A while back we faced the problem that when we use several lockins to excite the MC degrees of freedom, their relative phase was not known.  The solution suggested was to use one oscillator and several demodulators.

I have now modified the C1IOO.mdl so that this can be implemented.  Previously we were using the MC_ASS lockins for WFS work.  I have now separated the WFS and MC_ASS structures. 

Other jobs to be done in this context are:

1) The medm screens associated with WFS lockins need to be updated with new channel names.

2) The scripts associated with both MC_ASS decentering and WFS ouput matrix determination have to be updated with the new channel names.

3) I also deleted all medm screens in the $screens$/c1ioo/ directory after copying them to $screens$/c1ioo/bak/.  After installing the new c1ioo model $screens$/c1ioo directory now contains just the automatically created screens.  All other user made screens should go into $screens$/c1ioo/master/ directory

This is a pic of the new c1ioo model:

 

 c1ioo20111025.png

 

ELOG V3.1.3-