A while back we faced the problem that when we use several lockins to excite the MC degrees of freedom, their relative phase was not known. The solution suggested was to use one oscillator and several demodulators.
I have now modified the C1IOO.mdl so that this can be implemented. Previously we were using the MC_ASS lockins for WFS work. I have now separated the WFS and MC_ASS structures.
Other jobs to be done in this context are:
1) The medm screens associated with WFS lockins need to be updated with new channel names.
2) The scripts associated with both MC_ASS decentering and WFS ouput matrix determination have to be updated with the new channel names.
3) I also deleted all medm screens in the $screens$/c1ioo/ directory after copying them to $screens$/c1ioo/bak/. After installing the new c1ioo model $screens$/c1ioo directory now contains just the automatically created screens. All other user made screens should go into $screens$/c1ioo/master/ directory
This is a pic of the new c1ioo model:

|