Message ID: 5680
Entry time: Mon Oct 17 17:07:30 2011
In reply to: 5660
Reply to this: 5693
6650
|
Author: |
steve |
Type: |
Update |
Category: |
SUS |
Subject: |
ETMX oplev returning beam od 3 mm |
|
|
ETMX oplev had 6 mm diameter beam on the qpd. I relayed the beam path with 2 lenses to get back 3 mm beam on the qpd
BRC 037 -100 Bi _concave lens and PCX 25 200 VIS do the job. Unfortunately the concave lens has the AR 1064.
|
|
|