Thu Oct 13 23:58:38 2011, Koji, Update, LSC, fixing REFL165 
|
Sat Oct 15 16:42:08 2011, Koji, Update, LSC, Testing REFL165 
|
Sat Oct 15 17:06:20 2011, Koji, Update, LSC, Installation REFL165
|
Sun Oct 16 02:30:00 2011, rana, Update, Electronics, Testing REFL165
|
Wed Mar 1 17:25:28 2017, Steve, Update, LSC, MCREFL condition pictures   
|
Fri Mar 17 14:49:09 2017, gautam, Update, LSC, MCREFL condition pictures  
|
|
Message ID: 5673
Entry time: Sun Oct 16 02:30:00 2011
In reply to: 5671
|
Author: |
rana |
Type: |
Update |
Category: |
Electronics |
Subject: |
Testing REFL165 |
|
|
Unless the bias feedback circuit has been tuned for the 1 mm diode, its possible that you are seeing some C(V) effects. Its easy to check by looking at the phase response at 165 MHz v. the DC photocurrent. Then the feedback or feedforward gain can be tuned.
|