40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Sep 27 20:02:19 2011, Koji, Update, SUS, Watchdog rearmed 
    Reply  Wed Sep 28 00:06:21 2011, Jenne, Update, SUS, Watchdog rearmed 
Message ID: 5560     Entry time: Wed Sep 28 00:06:21 2011     In reply to: 5559
Author: Jenne 
Type: Update 
Category: SUS 
Subject: Watchdog rearmed 

Quote:

I came to the control room and found the PMC and IMC were unlocked. ==> Relocked
I found the watch dogs of the vertex suspensions are tripped.

I checked the data for the past 6 hours and found they are independent events.
The unlock of the MCs occured 4 hours ago and the watchdogs tripped 2 hours ago.

The suspension damping was restored at around 7:50PM PDT.

 Oops, I should have noticed all of those things.  Several hours of computer-battle exhausted me.  Thanks Koji.

ELOG V3.1.3-