40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Mon Sep 19 23:19:40 2011, Keiko, Update, IOO, AM modulation mistery
|
Tue Sep 20 23:01:37 2011, Keiko, Update, IOO, AM modulation mistery
|
Wed Sep 21 16:44:18 2011, Keiko, Update, IOO, AM modulation mistery 
|
Wed Sep 21 17:42:35 2011, rana, Update, IOO, AM modulation misery
|
Wed Sep 21 18:53:03 2011, Keiko, Update, IOO, AM modulation misery  
|
Wed Sep 21 21:13:35 2011, rana, Update, IOO, AM modulation misery
|
Thu Sep 22 17:29:42 2011, Keiko, Update, IOO, AM modulation mistery    
|
Sat Sep 24 09:55:42 2011, Keiko, Update, IOO, AM modulation mistery
|
|
Message ID: 5472
Entry time: Mon Sep 19 23:19:40 2011
Reply to this: 5491
|
Author: |
Keiko |
Type: |
Update |
Category: |
IOO |
Subject: |
AM modulation mistery |
|
|
Keiko, Anamaria
We started to investigate the AM modulation mistery again. Checking just after the EOM, there are AM modulation about -45dBm. Even if we adjust the HWP just before the EOM, AM components grow up in 5 mins. This is the same situation as before. Only the difference from before is that we don't have PBS and HWP between the EOM and the monitor PD. So we have a simpler setup this time.
We will try to align the pockells cell alignment tomorrow daytime, as it may be a problem when the crystal and the beam are not well parallel. This adjustment has been done before and it didn't improve AM level at that time. |