Entry  Fri Sep 16 22:51:52 2011, Paul, Update, SUS, Calibration plan for the oplevs 
    Reply  Sun Sep 18 14:08:52 2011, rana, Update, SUS, Calibration plan for the oplevs 
Message ID: 5448     Entry time: Sun Sep 18 14:08:52 2011     In reply to: 5443
Author: rana 
Type: Update 
Category: SUS 
Subject: Calibration plan for the oplevs 

We don't need a high quality calibration for the optical levers. ~50% accuracy is fine.

For that you can use the OSEM calibration of ~1.7 V/mm (its less than 2 since the OSEMs have been degrading) or you can use the cavity power method that Kakeru used; it worked just fine. There's no benefit in trying for a 1% number for optical levers.