Entry  Fri Sep 9 16:16:59 2011, kiwamu, Update, IOO, spot positions on MC mirrors (in-vac) 
    Reply  Fri Sep 9 20:52:59 2011, kiwamu, Update, IOO, spot positions on MC mirrors (in-vac) 
Message ID: 5371     Entry time: Fri Sep 9 16:16:59 2011     Reply to this: 5373
Author: kiwamu 
Type: Update 
Category: IOO 
Subject: spot positions on MC mirrors (in-vac) 

The spot positions on the MC mirrors were measured in the vacuum condition.

The obtained spot positions are quite bad and roughly at 2-3 mm level. We have to realign the beam axis and the MC mirrors.

 

    Feb 26 2011      May 08 2011 Aug 2 2011  Aug 10 2011 (in air) Aug 14 2011 (in air)

Aug 23 2011 (in air)

[NEW]  Sep 9 2011
MC1 pit [mm]   1.6   1.9  1.93 -0.858 -0.2 0.1354  -1.55
MC2 pit [mm]   6.4   9.0 9.03 -0.844 -0.8 -0.2522  -2.28
MC3 pit [mm]   1.4   2.0 2.01 -1.03 -0.1 -0.1383  -1.8
MC1 yaw [mm]   -1.5   -1.7 -1.72 -0.847 -1.1 -1.0893  -0.02
MC2 yaw [mm]   1.0   0.2 0.178 0.582 0.6 0.7122  3.52
MC3 yaw [mm]   -1.3   -1.9 -1.87 -1.06 -1.1 -1.5587  -2.145

 