Message ID: 5349     Entry time: Tue Sep 6 21:33:21 2011
Author: Jenne 
Type: Update 
Category: SUS 
Subject: Diagonalizability of ITMX and ITMY is acceptable 

[Rana and Kiwamu on ITMX, Jenne and Suresh on ITMY, Zombie/brains meeting on accepting the matricies]

 

Optic Spectra Matrix "Badness"
ITMX ITMX.png       pit     yaw     pos     side    butt
UL    0.584   0.641   1.396  -0.578   0.558 
UR    0.755  -1.359   0.120  -0.286   0.262 
LR   -1.245  -0.139   0.604  -0.388   0.511 
LL   -1.416   1.861   1.880  -0.681  -2.669 
SD   -0.753   0.492   3.263   1.000  -1.523 
 5.85983
ITMY  ITMY.png           pit     yaw     pos     side    butt
UL    1.000   0.572   1.134  -0.059   0.951  
UR    0.578  -1.428   0.916  -0.032  -1.024  
LR   -1.422  -0.531   0.866  -0.009   1.086  
LL   -1.000   1.469   1.084  -0.036  -0.939  
SD   -0.662   0.822   1.498   1.000   0.265  
4.47727
 

 OSEMs were tweaked.  We have decided that both ITMs are okay in terms of their diagonalization.  ITMY isn't stellar when you look at the spectra, but it's kind of close enough.  Certainly the matrix looks fine.

Aside from checking on POX, I think we're now ready to close up.  Check back later tonight for a final decision announced on the elog.