Message ID: 525     Entry time: Fri Jun 6 16:47:04 2008
Author: josephb 
Type: Configuration 
Category: Cameras 
Subject: GC650 scatter images of 1064nm light 
Took images similar to the scattered light images from earlier, except with the CCD GC650 camera. The first three attached plots are an average of all 200 images, an average of the first 100 and then an average of the last 100 images.

They show no definite structure. The big red blob which changes with time may be a brighter reflection, although it virtually the same type of setup as the GC750 images.

To do this properly, I should grab a short focal length lens and simply blow up the beam to a size greater than the detector area and simply fix both cameras looking into.

The last set of plots are mean and standard deviation plots from a previous set of runs on 5/29/08 with the GC750 and GC650 running at the same time. The GC650 was receiving approximately 33% of the total power and GC750 was receiving 66% (in otherwords a factor of 2 more).
Attachment 1: GC650_scatter_200.pdf  41 kB  | Hide | Hide all
GC650_scatter_200.pdf
Attachment 2: GC650_scatter_100a.pdf  44 kB  | Hide | Hide all
GC650_scatter_100a.pdf
Attachment 3: GC650_scatter_100b.pdf  43 kB  | Hide | Hide all
GC650_scatter_100b.pdf