Data taken from: 997530498+120
Things are actually looking ok at the moment. "Badness" (cond(B)) is below 6 for all optics.
- We don't have results from PRM since its spectra looked bad, as if it's being clamped by the earthquake stops.
- The SRM matrix definitely looks the nicest, followed by ITMX. All the other matrices have some abnormally high or low elements.
- cond(B) for ETMY is better than that for SRM, even though the ETMY matrix doesn't look as nice. Does this mean that cond(B) is not necessarily the best figure of merit, or is there something else that our naive expectation for the matrix doesn't catch?
We still need to go through and adjust all the OSEM ranges once the IFO is aligned and we know what our DC biases are. We'll repeat this one last time after that.
TM |
|
M |
cond(B) |
BS |
 |
pit yaw pos side butt
UL 1.456 0.770 0.296 0.303 1.035
UR 0.285 -1.230 1.773 -0.077 -0.945
LR -1.715 -0.340 1.704 -0.115 0.951
LL -0.544 1.660 0.227 0.265 -1.070
SD 0.612 0.275 -3.459 1.000 0.046 |
5.61948 |
SRM |
 |
pit yaw pos side butt
UL 0.891 1.125 0.950 -0.077 0.984
UR 0.934 -0.875 0.987 -0.011 -0.933
LR -1.066 -1.020 1.050 0.010 1.084
LL -1.109 0.980 1.013 -0.056 -0.999
SD 0.257 -0.021 0.304 1.000 0.006 |
4.0291 |
ITMX |
 |
pit yaw pos side butt
UL 0.436 1.035 1.042 -0.068 0.728
UR 0.855 -0.965 1.137 -0.211 -0.969
LR -1.145 -1.228 0.958 -0.263 1.224
LL -1.564 0.772 0.863 -0.120 -1.079
SD -0.522 -0.763 2.495 1.000 -0.156 |
4.55925 |
ITMY |
 |
pit yaw pos side butt
UL 1.375 0.095 1.245 -0.058 0.989
UR -0.411 1.778 0.975 -0.022 -1.065
LR -2.000 -0.222 0.755 0.006 1.001
LL -0.214 -1.905 1.025 -0.030 -0.945
SD 0.011 -0.686 0.804 1.000 0.240 |
4.14139 |
ETMX |
 |
pit yaw pos side butt
UL 0.714 0.191 1.640 0.404 1.052
UR 0.197 -1.809 1.758 -0.120 -1.133
LR -1.803 -1.889 0.360 -0.109 0.913
LL -1.286 0.111 0.242 0.415 -0.902
SD 1.823 -3.738 -0.714 1.000 -0.130 |
5.19482 |
ETMY |
 |
pit yaw pos side butt
UL 1.104 0.384 1.417 0.351 1.013
UR -0.287 -1.501 1.310 -0.074 -1.032
LR -2.000 0.115 0.583 -0.045 0.777
LL -0.609 2.000 0.690 0.380 -1.179
SD 0.043 -0.742 -0.941 1.000 0.338 |
3.57032 |
|