Mon Aug 15 14:10:56 2011, Jenne, Update, SUS, Monday SUS update 7x
|
Mon Aug 15 17:36:10 2011, jamie, Update, SUS, Strangeness with ETMY (was: Monday SUS update)
|
Tue Aug 30 09:51:37 2016, Steve, Update, SUS, the chamber HEPA tents are back 
|
Wed Aug 31 23:01:02 2016, gautam, Update, SUS, the chamber HEPA tents are back
|
Thu Sep 1 15:40:52 2016, Steve, Update, SUS, HEPAs on each chamber door
|
|
Message ID: 5239
Entry time: Mon Aug 15 14:10:56 2011
Reply to this: 5241
12453
|
Author: |
Jenne |
Type: |
Update |
Category: |
SUS |
Subject: |
Monday SUS update |
|
|
The moral of the story here is that none of the suspensions are overwhelmingly awesome, but most of them will be fine if we leave them as-is.
SUS |
DoF Plot |
Input Matrix |
"BADness" (1==good) |
ITMX |
 |
pit yaw pos side butt
UL 0.438 1.019 1.050 -0.059 0.717
UR 0.828 -0.981 1.128 -0.215 -0.956
LR -1.172 -1.201 0.950 -0.275 1.241
LL -1.562 0.799 0.872 -0.120 -1.087
SD -0.579 -0.847 2.539 1.000 -0.170
|
4.68597
|
ITMY |
 |
pit yaw pos side butt
UL 1.157 0.185 1.188 -0.109 0.922
UR 0.020 -1.815 0.745 -0.051 -0.970
LR -1.980 -0.090 0.812 -0.024 1.158
LL -0.843 1.910 1.255 -0.082 -0.949
SD -0.958 1.080 1.859 1.000 0.325 |
4.82756 |
ETMX |
 |
pit yaw pos side butt
UL 0.338 0.476 1.609 0.316 1.046
UR 0.274 -1.524 1.796 -0.069 -1.180
LR -1.726 -1.565 0.391 -0.100 0.938
LL -1.662 0.435 0.204 0.286 -0.836
SD 0.996 -2.629 -0.999 1.000 -0.111
|
4.32072 |
ETMY |
 |
pit yaw pos side butt
UL 1.123 0.456 1.812 0.231 0.936
UR -0.198 -1.489 0.492 -0.096 -1.098
LR -2.000 0.055 0.188 -0.052 0.764
LL -0.679 2.000 1.508 0.275 -1.201
SD 0.180 -0.591 3.355 1.000 0.200 |
10.643 |
BS |
 |
pit yaw pos side butt
UL 1.575 0.697 0.230 0.294 1.045
UR 0.163 -1.303 1.829 -0.133 -0.958
LR -1.837 -0.308 1.770 -0.171 0.944
LL -0.425 1.692 0.171 0.257 -1.053
SD 0.769 0.345 -3.380 1.000 0.058 |
6.111
|
PRM |
 |
pit yaw pos side butt
UL 0.597 1.553 2.000 -0.469 1.229
UR 1.304 -0.447 0.383 -0.043 -0.734
LR -0.696 -1.048 -0.277 0.109 0.687
LL -1.403 0.952 1.340 -0.317 -1.350
SD 0.518 -1.125 -1.161 1.000 0.394
|
8.43363 |
SRM |
 |
pit yaw pos side butt
UL 0.831 1.039 1.153 -0.140 1.065
UR 1.071 -0.961 1.104 -0.057 -1.061
LR -0.929 -0.946 0.847 -0.035 0.837
LL -1.169 1.054 0.896 -0.118 -1.037
SD 0.193 -0.033 1.797 1.000 0.045 |
4.17396 |
|