Entry  Mon Aug 15 10:58:52 2011, kiwamu, Update, IOO, MC misaligned a lot 
    Reply  Mon Aug 15 14:07:39 2011, kiwamu, Update, IOO, Re: MC misaligned a lot 
Message ID: 5238     Entry time: Mon Aug 15 14:07:39 2011     In reply to: 5236
Author: kiwamu 
Type: Update 
Category: IOO 
Subject: Re: MC misaligned a lot 

The leveling was still okay. The MC mirrors were realigned and now they all are fine.

We will go ahead for the vertex alignment and extraction of the pick-off beams.

 

Here is a summary of the spot measurement.

    Feb 26 2011      May 08 2011 Aug 2 2011  Aug 10 2011 (in air) [NEW!!] Aug 14 2011 (in air)
MC1 pit [mm]   1.6   1.9  1.93 -0.858 -0.2
MC2 pit [mm]   6.4   9.0 9.03 -0.844 -0.8
MC3 pit [mm]   1.4   2.0 2.01 -1.03 -0.1
MC1 yaw [mm]   -1.5   -1.7 -1.72 -0.847 -1.1
MC2 yaw [mm]   1.0   0.2 0.178 0.582 0.6
MC3 yaw [mm]   -1.3   -1.9 -1.87 -1.06 -1.1

 

Quote from #5236

Anyways we should check the leveling of the IOO table and the spot positions on the MC mirrors again to make sure.

 