Wed Aug 10 14:27:39 2011, Ishwita , Manuel, Update, PEM, Calibration of Guralp and STS2
|
Wed Aug 10 14:35:39 2011, rana, Update, PEM, Calibration of Guralp and STS2
|
Wed Aug 10 15:17:39 2011, Ishwita, Manuel, Update, PEM, Calibration of Guralp and STS2
|
Thu Aug 11 09:39:25 2011, Ishwita, Manuel, Update, PEM, Calibration of Guralp and STS2
|
Thu Aug 11 11:50:56 2011, Manuel , Ishwita, Update, PEM, Calibration of Guralp and STS2
|
Thu Aug 11 16:15:59 2011, Ishwita, Manuel, Update, PEM, Calibration of Guralp and STS2
|
|
Message ID: 5175
Entry time: Wed Aug 10 15:17:39 2011
In reply to: 5174
Reply to this: 5185
|
Author: |
Ishwita, Manuel |
Type: |
Update |
Category: |
PEM |
Subject: |
Calibration of Guralp and STS2 |
|
|
Quote: |
I'm pretty sure that don't have any ADC's with this gain. It should be +/- 10V for 16 bits.
|
Jenne told us that the ADC was +/- 2V for 16 bits so our calibration is wrong. Since, the ADC is +/- 10V for 16 bits we need to change our calibration and now we can also use the purple STS breakout box. |