Message ID: 5174
Entry time: Wed Aug 10 14:35:39 2011
In reply to: 5172
Reply to this: 5175
|
Author: |
rana |
Type: |
Update |
Category: |
PEM |
Subject: |
Calibration of Guralp and STS2 |
|
|
I'm pretty sure that don't have any ADC's with this gain. It should be +/- 10V for 16 bits. |