40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 516     Entry time: Wed Jun 4 10:18:52 2008
Author: steve 
Type: Update 
Category: PSL 
Subject: wedged SS beam trap 
I moved the SS trap over to the psl table.
Texas super # 8 was used from the large shipment.
TXs#8 scattering measured as before, meaning the polishing is good.

Go's squeezing power pick up 350 mW was used.
I made two ~30 degrees wedge traps using 6" x 4" and 12" x 4" SS 0.039" thick
with copper backing of similar size.

There was too much scattering and I could not minimize them all.
It is very helpful to have so much space on the psl table.
It shows more of the weakness of this kind of trap.
I did not dare to turn up the power.
Attachment 1: trap1.png  1.224 MB  | Hide | Hide all
trap1.png
Attachment 2: trap2.png  1.216 MB  | Hide | Hide all
trap2.png
ELOG V3.1.3-