40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sat Nov 13 15:53:05 2010, yuta, Update, CDS, diagonalization of MC input matrix MCspectraNov09.pngMCspectraNov13.pngMC1spetra_wrongmatrix.png
    Reply  Sun May 15 03:58:19 2011, rana, Update, CDS, diagonalization of MC input matrix mc1.png
       Reply  Thu May 19 00:23:44 2011, rana, Update, CDS, diagonalization of MC input matrix 
       Reply  Sun Jun 26 16:17:22 2011, rana, Update, CDS, diagonalization of MC input matrix inMatDiag.pdf
          Reply  Mon Aug 8 00:12:58 2011, rana, Update, CDS, diagonalization of MC input matrix 
             Reply  Mon Aug 8 00:58:26 2011, rana, Update, CDS, diagonalization of MC input matrix null.png
                Reply  Wed Aug 10 00:21:10 2011, jamie, Update, CDS, updates to peakFit scripts 
                Reply  Sat Aug 27 15:47:59 2011, rana, Update, CDS, OSEM noise / nullstream and what does it mean for satellites Untitled.png
                   Reply  Wed Nov 30 01:35:49 2011, Jenne, Update, CDS, OSEM noise / nullstream and what does it mean for satellites 
             Reply  Mon Aug 8 19:45:27 2011, jamie, Update, CDS, activateDQ script run; SUS channels being acquired again 
Message ID: 5137     Entry time: Mon Aug 8 00:58:26 2011     In reply to: 5136     Reply to this: 5162   5312
Author: rana 
Type: Update 
Category: CDS 
Subject: diagonalization of MC input matrix 

Besides the purpose of correctly tuning the suspensions, my hidden goal in the input matrix diagonalization has been to figure out what the 'true' sensing noise of the OSEMs is so that we can accurately predict the noise impact on the OAF.

The attached plot shows the DOFs of ITMX calibrated into microns or microrad as per Jamie's ethereal input matrix calculations.

The main result is in the ratio of POS to BUTTER. It tells us that even at nighttime (when this data was taken) we should be able to get some reduction in the arms at 1 Hz.

Whether we can get anything down to 0.1 Hz depends on how the arm control signal compares to the POS signal here. I leave it to Jenne to overlay those traces using a recent Arm lock.