The table below gives the OSEM positions as seen on the slow chanels C1:SUS-ETMX_{UL,UR,LL,LR,SD}PDMon

Note that the side OSEM has the fast channel (OUTPUT) available and we used that to locate it.
When we began work the OSEMs were photographed so that we have a record of their locations till now. It was difficult to get accurate estimate of the magnet offset inside the OSEM we could not see the screen on the camera while clicking. We then took some pictures after finishing the work. These are given below

The picture of the left is from before OSEMs were moved. It can be seen that OSEMs are rotated to make sure that the magnets avoid touching the teflon sheets which hold the shadow sensors. The picture on the right shows the positions of the OSEMs after we adjusted their positions. This time we kept the teflon sheets vertical as shown to minimise the coupling between the Side and Axial directions.
We needed to reposition them once again after we moved the tower to the center of the table.
Pictures with more detail will be posted to the wiki later.
|